Troubleshooting
| Problem | Cause | Remedy |
|---|---|---|
| The machine does not turn on. | The main switch is off (positioned on “O”). (Cap.6) | Press the switch into position “I”. |
| The machine is not plugged in. | Insert the plug in a suitable outlet. | |
| The tap leaks (liquid leaks from below). | The tap plug is not lubricated. (Fig.58) | Lubricate the plug and OR. |
| The plug is defective. | Replace the plug. | |
| The tap leaks (liquid leaks from above). | The OR is defective. | Replace the OR. |
| The OR is not lubricated.(Fig.58) | Lubricate the plug and OR. | |
| Product leaks from the rear part of the bowl. | The bowl is not fit correctly in place . (Par.7.5) | Check the positioning of the bowl. |
| The bowl seal is not lubricated. (Fig.53) | Lubricate accordingly. | |
| The seal is defective. | Replace the seal. | |
| The auger does not turn | The switch is positioned on “O”. (Cap.6) | Press the switch into position “I”. |
| Blocks of ice inside the bowl. | Switch off the machine, allow the bowl contents to melt and check that the product has been correctly diluted. | |
| The machine does not make granita. | The switches are off. (Cap.6) | Press the switch into position “I”. |
| The machine is near sources of heat. | Install the machine in a suitable place. | |
| There is insufficient ventilation. | ||
| The condenser is dirty. (Par.7.10.) | Call in a specialized technician to clean the condenser. | |
| The consistency has not been regulated correctly. (Par.6.6) | Correctly regulate the consistency. | |
| The auger is noisy. | The front seal has been applied incorrectly. (Fig.51) | Check that the seal is applied correctly. |
| The seal is not lubricated. (Fig.52) | Lubricate the seal accordingly. | |
| The thermometer does not indicate the temperature. | The battery has run out | Replace the battery (Section 7.9.) |
| Probe fault | Call a specialized technician | |
| The lighted lid does not work | It is not plugged in properly | Check that the plug is properly connected |
| The switch is on “O” | Switch on the lid lamp using the switch | |
| Burnt-out bulb | Replace the bulb (Section 7.8.) | |
| The tap does not dispense | Blocks of ice inside the bowl. | Switch off the machine, allow the bowl contents to melt and check that the product has been correctly diluted. |
| If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do not solve the problem, contact a specialized technician. | ||